Moving Light Accessories Top Hats Accessory Holder Adapter Barndoor Beam Bender Blacktak™ Light Mask Foil Colour Extender Colour Frame Concentric Ring Donut Drop-In Boomerang Drop-In Iris Egg Crate Louver Glass Holder Image Multiplexer™ Lighting Shield Mainframe Sandwich Holder Chroma-Q Color Force / Color Kinetics Accessories
- Hardware >
- Software >
PWREP DIN Mount Opto Splitters
There are various types of PWREP DIN Mount Opto Splitters, or DMX-RDM Repeaters with Merging, in the Pathway Connectivity system.
Learn more about these products below, or in Pathway Connectivity's PWREP DIN Mount Opto Splitter product page.
The DMX Repeater, DIN-mount, 4-Ports, DMX Only, Part Number: PWREP DIN P4 NONRDM (Legacy Name: eDIN Opto-Splitter, Legacy P/N: P1002) is an essential part of any permanent DMX512 distribution system. The DIN-rail mountable eDIN Opto-Splitter enables ‘star’ wiring configurations of DMX512 data lines. Each buffered output is isolated from the DMX input and protects all connected end-devices from harmful electrical faults and ground loops.
The DMX Interface, DIN-mount, 12 Contact Closure Relay (8"), Part Number: PWINF DIN CC (Legacy Name: eDIN Contact Closure, Legacy P/N: P1003) interface provides twelve DMX-controlled dry contact closures for both power and signal level switching. It provides DMX512 control over twelve form-C relays, for signal level switching, in a DIN-rail mountable format. Each relay may be independently wired for normally-open (NO) or normally closed (NC) operation. Field configurable through front panel or by RDM, the eDIN Contact Closure has nine operating modes for maximum flexibility of use.
The DMX Interface, DIN-mount, 16 Channel Demultiplexer (6.25"), Part Number: PWINF DIN D2A (Legacy Name: eDIN Demultiplexer, Legacy P/N: P1004) converts DMX512 signals to 0-10VDC, or other common DC ranges, or to current-sinking control of LED drivers, Mark 7-type fluorescent ballasts, or solid state relays. The eDIN Demultiplexer converts DMX512 to 16 channels of analogue DC output voltage. Diode shunts allow user-selection between current sourcing applications is typically for theatrical dimmers, current-sinking control, or for LED fixture driver s or Mark VII electronic fluorescent ballast control. A non-dim mode supports solid-state relay control.
The DMX Interface, DIN-mount, 24 Channel Analog to Digital (6.25"), Part Number: PWINF DIN A2D (Legacy Name: DIN Analog-to-DMX, Legacy P/N: P1006) converts analogue voltages or dry contact input to DMX512. It converts 24 analogue 0-10VDC sources or 24 dry contact closures into a DMX512 signal. A built-in DMX merger combines signal output with other in-line eDIN Analogue-to-DMX interfaces, lighting consoles, or controllers. Also may be used as a simple snapshot playback device, holding up to 24 ‘looks’.
The DMX Repeater, DIN-mount, 4-Ports, E1.20 RDM Compliant, Part Number: PWREP DIN P4 RDM (Legacy Name: eDIN DMX/RDM Splitter, Legacy P/N: P1009) provides full isolation between ports and RDM-compatibility. It is a DIN-rail mountable four-way opto-splitter that supports the bi-directional communication standard E1.20 Remote Device Management (“RDM”), as well as DMX512. Used in installations that require ‘star’ wiring configurations, all output ports are separate electrical entities, fully opto-isolated and independently protected against fault voltages.
The DMX Repeater, DIN-mount, 8-Ports, Merge, Priority, HTP and Hub, RDM Compliant, Part Number: PWREP DIN P8 RDMHUB (Legacy Name: eDIN DMX/RDM Hub, Legacy P/N: P1016) brings flexibility to single universe DMX512 distribution systems. Through use of automatic signal sensing across four operating modes, any port may detect incoming DMX signals and act as an input, or: two inputs may be merged, the user may choose between inputs, or a priority scheme may be invoked. This device is RDM discoverable and configured.
The DMX Repeater, DIN-mount, 3-Ports, Merge, Priority, HTP and Hub, RDM Compliant, Part Number: PWREP DIN P3 RDMHUB (Legacy Name: DMX/RDM Merger, Legacy P/N: P1017) allows merging and switching between two DMX sources in a one-universe system. Through the use of automatic signal sensing across four operating modes, any port may detect incoming DMX signals and act as an input and produces two outputs; or two inputs may be merged to create one output; based on priority, HTP merge or switchable using an external contact. The P1017 is RDM discoverable and configured.
Additional Information
DMX Repeater, DIN-mount, 4-Ports, DMX Only, Part Number: PWREP DIN P4 NONRDM:
(Legacy Name: eDIN Opto-Splitter, Legacy P/N: P1002)
- One DMX512 input
- Four buffered DMX512 outputs
- One passive DMX512 thru connector
- Pluggable terminal blocks for all connectors
- Power and data easily daisy-chained between modules
- DMX IN indicator
- DC Power input indicator
- ISO 5V indicator
- Termination switch
- No fuses— self-resetting port protection recovers from voltage faults
- DIN rail mounting section included
DMX Interface, DIN-mount, 12 Contact Closure Relay (8"), Part Number: PWINF DIN CC:
(Legacy Name: eDIN Contact Closure, Legacy P/N: P1003)
- DMX512 start address and operating mode may be set from front panel interface or remotely using E1.20 RDM
- DMX512-present relay (normally open or normally closed)
- Indicator LEDs for power, processor, DMX input, and relay status
- Pluggable terminal block connections accept solid or stranded wire between #26 and #16 AWG
- Normally open or normally closed wiring option for each relay
- User-adjustable trigger threshold (default to 50%)
- One DMX512-A/RDM data input connection
- One passive DMX512-A data through connection
- Suitable as pilot relay for high voltage contactors, with adequate arc protection (by others)
- Data and power easily daisy-chained between modules
- Termination switch
- User-initiated diagnostics and test modes
- Firmware field-upgradable using RDM (requires Pathway Pathport gateway and RDM utility program)
DMX Interface, DIN-mount, 16 Channel Demultiplexer (6.25"), Part Number: PWINF DIN D2A:
(Legacy Name: eDIN Demultiplexer, Legacy P/N: P1004)
- DMX512 start address and operating mode may be set from front panel interface or remotely using E1.20 RDM
- Indicator LEDs for power, processor, and DMX input status
- Standard DC output modes of 0-10V, 0-15V, 0-2.5V, or 0-5V
- Custom mode allows user-set minimum and maximum DC output up to 16V
- EFBC/LED Driver mode allows single DMX channel control of mains voltage (via SSR) and 0-10V dimming
- Maximum current rating per output of 10mA (sourcing) or 30mA (sinking)
- CCL “Panic Input” drives all outputs to full
- Pluggable terminal block connections accept solid or stranded wire between #26 and #16 AWG
- One DMX512-A/RDM data input connection
- One passive DMX512-A data through connection
- Data and power easily daisy-chained between modules
- Termination switch
- Firmware field-upgradable using RDM (requires Pathway Pathport gateway and RDM utility program)
DMX Interface, DIN-mount, 24 Channel Analog to Digital (6.25"), Part Number: PWINF DIN A2D
(Legacy Name: DIN Analog-to-DMX, Legacy P/N: P1006)
- DMX512 start address and operating mode may be set from front panel interface or remotely using E1.20 RDM
- Indicator LEDs for power, processor, DMX input status and contact closure operation
- Convert 0-10VDC input to DMX512 output levels
- Alternate contact closure mode, for off/full DMX control
- Recall mode allows capture and playback of up to 24 discrete, full universe ‘looks’
- LED indicator for CCI mode
- Built-in merger allows in-line operation with other DMX sources in either recall or input modes
- One DMX512-A/RDM data input connection
- One passive DMX512-A data through connection
- Data and power easily daisy-chained between modules
- Termination switch
- Independent test function, in both analogue and contact closure modes
- Firmware field-upgradable using RDM (requires Pathway Pathport gateway and RDM utility program)
DMX Repeater, DIN-mount, 4-Ports, E1.20 RDM Compliant, Part Number: PWREP DIN P4 RDM
(Legacy Name: eDIN DMX/RDM Splitter, Legacy P/N: P1009)
- One DMX512 /RDM input port
- Four fully isolated DMX512/RDM bi-directional output ports
- One active DMX512/RDM bi-directional thru port
- Pluggable terminal blocks for all connectors
- Power and data easily daisy-chained between modules
- DMX IN indicator
- DC Power input indicator
- ISO 5V indicator
- Auto-termination of DMX THRU
- No fuses— self-resetting port protection recovers from voltage faults
DMX Repeater, DIN-mount, 8-Ports, Merge, Priority, HTP and Hub, RDM Compliant, Part Number: PWREP DIN P8 RDMHUB (Legacy Name: eDIN DMX/RDM Hub, Legacy P/N: P1016)
- Eight bi-directional ports
- Four operating modes
- Simple UI for mode selection
- Automatically locates incoming DMX signal and routes according to current mode
- Act as automated signal patch bay
- Auto-termination of inputs
- Port direction LED indicators, as well as power and function
- E1.20 Remote Device Management support in routing modes
- Hold last look time and output speed user-settable by RDM
- Multi-level cascade of modules permitted
- Pluggable terminal block connections accept solid or stranded wire between #26 and #16 AWG
- Power easily daisy-chained between modules
DMX Repeater, DIN-mount, 3-Ports, Merge, Priority, HTP and Hub, RDM Compliant, Part Number: PWREP DIN P3 RDMHUB:
(Legacy Name: DMX/RDM Merger, Legacy P/N: P1017)
- Three bi-directional ports
- Four operating modes
- Simple UI for mode selection
- Pluggable screw terminal connector block for power IN and THRU to daisy-chain between modules
- Two sets of pluggable terminal blocks for all DMX512 connections to support both shielded twisted pair and CAT5/6
- Automatically locates incoming DMX signal and routes according to current mode (4 options):
- HUB: Sense input on any port and output to other two ports
- A/B: External A/B switch for user selection of input
- Priority: Automatically switch to Input A on active DMX signal, and fall back to Input B
- Merge: Merge Input A and B with highest level per slot output
- E1.20 Remote Device Management support in routing modes
- Auto-termination of inputs
- LEDs for Port direction, as well as power and function
- Hold last look time and output speed user-settable by RDM
- Multi-level cascade of modules permitted
- Firmware field-upgradable using RDM (requires Pathway Pathport gateway and Pathscape software)
DMX Repeater, DIN-mount, 4-Ports, DMX Only, Part Number: PWREP DIN P4 NONRDM:
(Legacy Name: eDIN Opto-Splitter, Legacy P/N: P1002)
- 1500V opto-isolation between input and output ports
- 250V fault protection on input and output ports
- Input operating voltage: 9-30 VDC
- 5W power consumption
- Operating conditions: -10 to +50°C; 10-90% relative humidity, non-condensing
DMX Interface, DIN-mount, 12 Contact Closure Relay (8"), Part Number: PWINF DIN CC:
(Legacy Name: eDIN Contact Closure, Legacy P/N: P1003)
- 12 Channel Maintained
- 12 Channel Momentary
- 12 Channel Momentary "ON"
- 6 Channel Momentary Split
- 6 Channel Maintained Split
- 12 Channel Momentary Split with Secondary "Reset"
- Chase
- Single Channel Select
- Single Channel Build
DMX Interface, DIN-mount, 16 Channel Demultiplexer (6.25"), Part Number: PWINF DIN D2A:
(Legacy Name: eDIN Demultiplexer, Legacy P/N: P1004)
- 1500V opto-isolation between input and output ports
- 250V fault protection on input and output ports
- Input operating voltage: 9-30 VDC
- 6W power consumption
- Operating conditions: -10°-50°C; 10-90% relative humidity, non-condensing
DMX Interface, DIN-mount, 24 Channel Analog to Digital (6.25"), Part Number: PWINF DIN A2D:
(Legacy Name: DIN Analog-to-DMX, Legacy P/N: P1006)
- 1500V opto-isolation between input and output ports
- 250V fault protection on input and output ports
- Input operating voltage: 9-30 VDC
- 6W power consumption
- Operating conditions: -10°-50°C; 10-90% relative humidity, non-condensing
DMX Repeater, DIN-mount, 4-Ports, E1.20 RDM Compliant, Part Number: PWREP DIN P4 RDM:
(Legacy Name: eDIN DMX/RDM Splitter, Legacy P/N: P1009)
- 2500V opto-isolation between input and output ports
- 250V fault protection on input and output ports
- Input operating voltage: 9-30 VDC
- 6W power consumption
- Operating conditions: -10° to +50°C; 10-90% relative humidity, non-condensing
DMX Repeater, DIN-mount, 8-Ports, Merge, Priority, HTP and Hub, RDM Compliant, Part Number: PWREP DIN P8 RDMHUB:
(Legacy Name: eDIN DMX/RDM Hub, Legacy P/N: P1016)
- 250V fault protection on input and output ports
- 250V fault protection on input and output ports
- Input operating voltage: 24-48 VDC
- 7W power consumption
- Operating conditions: -10to +48°C; 10-90% relative humidity, non-condensing
DMX Repeater, DIN-mount, 3-Ports, Merge, Priority, HTP and Hub, RDM Compliant, Part Number: PWREP DIN P3 RDMHUB:
(Legacy Name: DMX/RDM Merger, Legacy P/N: P1017)
- 250V fault protection on input and output ports
- Input operating voltage: 9-30 VDC
- 5W power consumption
- Operating conditions: -10° to +50°C (14° to 122°F); 10-90% relative humidity, non-condensing